I test

Le tubazioni EUROKLIMA sono state sottoposte a rigorosi

test, inclusi quelli ad alte e basse temperature e in condi-

zioni di elevata umidit

à.

Temperatura

L’obiettivo principale dei test è stato valutare la dispersio-

ne termica delle tubazioni EUROKLIMA in diverse condi-

zioni operative.

È stata analizzata l’efficacia dell’isolamen-

to monitorando le temperature della super

ficie esterna e

interna quando esposte a vari livelli di temperatura dell’ac-

qua e ambientali in condizioni controllate.

Le tubazioni sono state testate per la dispersione termica

posizionandole in una camera termostatica e similuando

le normali condizioni operative di un impianto di riscal-

damento con temperature ambientali di 0°C, 10°C, 20°C

e 30°C, e veicolando al loro interno acqua calda a 40°C,

50°C, 60°C e 70°C.

Sono state inoltre testate simulando le normali condizioni

operative di un impianto di raffrescamento, collocandole

in una camera termostatica con temperature ambientali di

25°C e 35°C, e veicolando al loro interno acqua refrigerata

a 6°C e 12°C.

I risultati dei test hanno dimostrato che le tubazioni EU-

ROKLIMA eccellono nella riduzione della dispersione ter-

mica in tutte le condizioni operative testate.

L’isolamento delle tubazioni assicura un controllo termico

stabile, dimostrando la sua ef

ficacia in impianti di riscalda-

mento e raffrescamento e in generale per dove si necessiti

di veicolare acqua calda o refrigerata.

Umidit

Le nostre tubazioni hanno superato con successo rigorosi

test per la verifica della formazione di condensa. Durante

il test, un

fluido a 7°C

è stato fatto circolare all’interno della

tubazione, che è poi stata esposta a camere termostatiche

con temperature di 20°C e umidità relative del 60%, 70%

e 80%.

Le tubazioni EUROKLIMA hanno mantenuto le loro carat-

teristiche funzionali, evitando la formazione di condensa

ed eliminando il rischio di degrado o corrosione.

Testing

EUROKLIMA pipes have been subjected to rigorous tests,

including those at high and low temperatures and in high hu-

midity.

Temperature

The main objective of the tests was to evaluate the heat loss

of EUROKLIMA pipes under different operating conditions.

The effectiveness of the insulation was analysed by moni-

toring external and internal surface temperatures when ex-

posed to various water and environmental temperature lev-

els under controlled conditions.

The pipes were tested for thermal dispersion by placing them

in a thermostatic chamber and simulating the normal oper-

ating conditions of a heating system with ambient temper-

atures of 0°C, 10°C, 20°C and 30°C, and by conveying hot

water inside them at 40°C, 50°C, 60°C and 70°C.

They were also tested by simulating the normal operating

conditions of a cooling system, placing them in a thermo-

static chamber with ambient temperatures of 25°C and 35°C,

and conveying chilled water inside them at 6°C and 12°C.

Test results showed that EUROKLIMA pipes excel in re-

ducing heat loss under all tested operating conditions.

The insulation of the pipes ensures stable thermal control,

proving its effectiveness in heating and cooling systems and

in general wherever hot or chilled water needs to be con-

veyed.

Humidity

Our pipes have successfully passed rigorous tests for con-

densation formation. During the test, a

fluid at 7°C was

circulated within the pipe, which was then exposed to ther-

mostatic chambers with temperatures of 20°C and relative

humidity of 60%, 70% and 80%.

The EUROKLIMA pipes maintained their functional charac-

teristics, avoiding the formation of condensation and elimi-

nating the risk of degradation or corrosion.