A. In the execution of all operations, the Legislative Decree 81/08 and subsequent modifications regarding the safety of temporary and
mobile building sites must be observed.
B. First, verify the integrity of the product and the tightness of joints and seals; signal the possible presence of defects. Verify if the
material corresponds to the order and to project data.
C. Verify that the modular tank is accompanied by all standard documentation (technical data sheets, underground installation
instructions, etc...), the internal components and when provided the electrical control panel. Copies of the documentation may be
requested by sending an email to: marketing@elbi.it
D. Ensure that all items not in polyethylene are appropriate for the fluid that will be inserted.
E. Use lifting/transport suitable for the capacity, and in compliance with current safety standards.
F. Avoid impacts and contact with sharp or sharp-edged objects that could damage the product.
G. Do not drag or haul the tank on the floor; the bottom could be damaged.
H. Move the tanks only when completely empty using the appropriate lifting eyes; never lift the tank by the inlet and/or outlet pipes.
I.
In case of tank complete with pump check that it is properly secured; communicate any defects;
J. Use flexible piping in the connections to the water supply to avoid any stress in the loading and unloading of the tank;
K. Verify that your project data communicated in your quote request (prevalence, capacity, etc.) have not changed. Otherwise,
immediately contact the Technical Office.
L. For the choice of backfill material and compaction methods, refer to European Standards ENV 1046 and UNI EN 1610.
M. Mark the area with appropriate signs during handling
A. It is absolutely forbidden to use the underground tank for outdoor use.
B. It is strictly forbidden to use the tank to store liquids which do not comply with the tank resistance chart
C. The underground tank DOES NOT conform and CANNOT be used for storing diesel fuel.
If you wish to use the tank above ground without it being declared fit to do so, the guarantee becomes invalid.
A. When installing a pump, it is mandatory to connect a pipe to the arrangement, adequately design for use in the open air, for the de-
aeration of the pump on the tank..
B. To handle the product use lifting/transport suitable for the capacity, and in compliance with current safety standards.
C. During transportation, avoid movements that may damage the tank.
D. Lift the tank only if completely empty.
E. Do not remain in the workspace during handling operations
F.
For lifting modular tanks use suitable ropes or straps resistant to the load to be supported. Place the lifting ropes or straps in the lifting
eyes on the top part of the modular tanks. To avoid imbalance of load, always place them symmetrically as shown below, matching the
angle-tail pull, which must not be less than 45°.