KESSEL AG

Catalogue EN 4.1

3.2 Pumping stations 153

Pumping station Aqualift S

For underground installation for wastewater without sewage and rainwater

EN 12050-2

Polyethylene storage chamber Ø 600 for underground

installation, resistant to aggressive media. With upper

section made of polymer, vertically adjustable, cover

class A in polymer load up to 600 kg, class B in cast iron

and concrete load up to 12.5 t and cover class D in cast

iron load up to 40 t. Groundwater resistant.

Inlet Ø 110 mm (GTF 600) or Ø 160 mm (GTF 1200), con-

nection for pipe gasket for Ø 110 according to EN 1401

and EN 12666-1 - each for ventilation or conduit pipe.

Installation: Handles groundwater depths up to 2.500 mm

With single or twin removable wastewater pump(s) with

multi-vane impeller for wastewater without sewage.

Available with float switch or pneumatic level measure-

ment. Pressure pipe Ø 40 mm outside diameter for PVC

glue connection, with integrated non-return flap, 10 mm

max solid size. Power cable length: 10 m (Schuko)

Control unit

Pneumatic versions with control unit with self-diagnosis

system (SDS), battery buffering and logbook function,

control unit is splashproof (IP 54).

Ø806

Pumping capacity

Note: Consider frost free depth of pressure pipe.

2

4

6

8

10 12 14Q[m

3

/h]

Pump type

GTF 600-S1*

GTF 1200-S3-50%*

Current type

Alternating current

Alternating current

Pumping

capacity

12 m

3

/h

15.5 m

3

/h

Pumping

height

8 m

9 m

*Definition of S1 and S3-pumps see page 97

Single station with one pump

and float switch

Single station with one pump with SDS con-

trol unit and pneumatic level measurement

Twin station with two pumps with SDS con-

trol unit and pneumatic level measurement

Pump

Cover class A/B

GTF 600

GTF 600

GTF 600

GTF 1200

GTF 1200

GTF 1200

Cover class D

GTF 600

GTF 600

GTF 600

GTF 1200

GTF 1200

GTF 1200

Installation depths

D in mm

800 – 1250

1300 – 1750

1800 – 2250

800 – 1250

1300 – 1750

1800 – 2250

800 – 1250

1300 – 1750

1800 – 2250

800 – 1250

1300 – 1750

1800 – 2250

Pump

Cover class A/B

GTF 600

GTF 600

GTF 600

GTF 1200

GTF 1200

GTF 1200

Cover class D

GTF 600

GTF 600

GTF 600

GTF 1200

GTF 1200

GTF 1200

Installation depths

D in mm

800 – 1250

1300 – 1750

1800 – 2250

800 – 1250

1300 – 1750

1800 – 2250

800 – 1250

1300 – 1750

1800 – 2250

800 – 1250

1300 – 1750

1800 – 2250

Art. no.

825 811B

825 821B

825 831B

827 811B

827 821B

827 831B

825 811D

825 821D

825 831D

827 811D

827 821D

827 831D

Pump

Cover class A/B

GTF 600

GTF 600

GTF 600

GTF 1200

GTF 1200

GTF 1200

Cover class D

GTF 600

GTF 600

GTF 600

GTF 1200

GTF 1200

GTF 1200

Installation depths

D in mm

800 – 1250

1300 – 1750

1800 – 2250

800 – 1250

1300 – 1750

1800 – 2250

800 – 1250

1300 – 1750

1800 – 2250

800 – 1250

1300 – 1750

1800 – 2250

Art. no.

824 811B

824 821B

824 831B

826 811B

826 821B

826 831B

824 811D

824 821D

824 831D

826 811D

826 821D

826 831D

Voltage

230 V

230 V

Art. no.

825 810B

825 820B

825 830B

827 810B

827 820B

827 830B

825 810D

825 820D

825 830D

827 810D

827 820D

827 830D

Amperage

2.9 A

4.9 A

Power (P1/P2)

650 W / 400 W

1180 W / 720 W

RPM

2.800 min

-1

2.800 min

-1

Protection

IP 68

IP 68

H [m]

9

8

7

6

5

4

3

2

1

Motor

protection

integrated

integrated

GTF 600

GTF 1200

P

u

m

p

i

n

g

s

t

a

t

i

o

n

s

7

0

0

/

1

2

0

0

/

1

7

0

0

4

0

0

4

8

2

/

8

9

4

/

1

3

9

4

I

n

s

t

a

l

l

a

t

i

o

n

d

e

p

t

h

s

D

3.2