KESSEL AG
Catalogue EN 4.1
For underground installation for wastewater without sewage and rainwater
EN 12050-2
Polyethylene storage chamber Ø 600 for underground
installation, resistant to aggressive media. With upper
section made of polymer, vertically adjustable, cover
class A in polymer load up to 600 kg, class B in cast iron
and concrete load up to 12.5 t and cover class D in cast
iron load up to 40 t. Groundwater resistant.
Inlet Ø 110 mm (GTF 600) or Ø 160 mm (GTF 1200), con-
nection for pipe gasket for Ø 110 according to EN 1401
and EN 12666-1 - each for ventilation or conduit pipe.
Installation: Handles groundwater depths up to 2.500 mm
With single or twin removable wastewater pump(s) with
multi-vane impeller for wastewater without sewage.
Available with float switch or pneumatic level measure-
ment. Pressure pipe Ø 40 mm outside diameter for PVC
glue connection, with integrated non-return flap, 10 mm
max solid size. Power cable length: 10 m (Schuko)
Control unit
Pneumatic versions with control unit with self-diagnosis
system (SDS), battery buffering and logbook function,
control unit is splashproof (IP 54).
Ø806
Note: Consider frost free depth of pressure pipe.
2
4
6
8
10 12 14Q[m
3
/h]
GTF 600-S1*
GTF 1200-S3-50%*
Current type
Alternating current
Alternating current
Pumping
capacity
12 m
3
/h
15.5 m
3
/h
Pumping
height
8 m
9 m
*Definition of S1 and S3-pumps see page 97
Pump
Cover class A/B
GTF 600
GTF 600
GTF 600
GTF 1200
GTF 1200
GTF 1200
Cover class D
GTF 600
GTF 600
GTF 600
GTF 1200
GTF 1200
GTF 1200
Installation depths
D in mm
800 – 1250
1300 – 1750
1800 – 2250
800 – 1250
1300 – 1750
1800 – 2250
800 – 1250
1300 – 1750
1800 – 2250
800 – 1250
1300 – 1750
1800 – 2250
Pump
Cover class A/B
GTF 600
GTF 600
GTF 600
GTF 1200
GTF 1200
GTF 1200
Cover class D
GTF 600
GTF 600
GTF 600
GTF 1200
GTF 1200
GTF 1200
Installation depths
D in mm
800 – 1250
1300 – 1750
1800 – 2250
800 – 1250
1300 – 1750
1800 – 2250
800 – 1250
1300 – 1750
1800 – 2250
800 – 1250
1300 – 1750
1800 – 2250
Art. no.
825 811B
825 821B
825 831B
827 811B
827 821B
827 831B
825 811D
825 821D
825 831D
827 811D
827 821D
827 831D
Pump
Cover class A/B
GTF 600
GTF 600
GTF 600
GTF 1200
GTF 1200
GTF 1200
Cover class D
GTF 600
GTF 600
GTF 600
GTF 1200
GTF 1200
GTF 1200
Installation depths
D in mm
800 – 1250
1300 – 1750
1800 – 2250
800 – 1250
1300 – 1750
1800 – 2250
800 – 1250
1300 – 1750
1800 – 2250
800 – 1250
1300 – 1750
1800 – 2250
Art. no.
824 811B
824 821B
824 831B
826 811B
826 821B
826 831B
824 811D
824 821D
824 831D
826 811D
826 821D
826 831D
Voltage
230 V
230 V
Art. no.
825 810B
825 820B
825 830B
827 810B
827 820B
827 830B
825 810D
825 820D
825 830D
827 810D
827 820D
827 830D
Amperage
2.9 A
4.9 A
Power (P1/P2)
650 W / 400 W
1180 W / 720 W
RPM
2.800 min
-1
2.800 min
-1
Protection
IP 68
IP 68
H [m]
9
8
7
6
5
4
3
2
1
Motor
protection
integrated
integrated
GTF 600
GTF 1200
P
u
m
p
i
n
g
s
t
a
t
i
o
n
s
7
0
0
/
1
2
0
0
/
1
7
0
0
4
0
0
4
8
2
/
8
9
4
/
1
3
9
4
I
n
s
t
a
l
l
a
t
i
o
n
d
e
p
t
h
s
D