58

1.2 Backwater chambers

Backwater inspection chamber Ø 1000 with Controlfix

For underground installation

Catalogue EN 4.1

Installation depth

in mm

KESSEL AG

Art. no.

881005

881505

882005

882505

883005

05-DN 150

05-DN 150

05-DN 150

05-DN 150

05-DN 150

333

Z-42.1-333

Polyethylene PE-HD.

Monolithic design, with open continuous channel and

clean out Controlfix, with integrated access steps,

watertight, resistant to aggressive wastewater, with

telescopic height-adjustable protective cover made

of polymer for use during the construction period

(can be used as a cover in green areas).

Triple 160 mm hub type gasketed inlets (left and right

inlets with open channel passage through chamber,

center hub inlet connected to housing for insertion of

KESSEL backwater valve). Available backwater valve

options - KESSEL Staufix SWA, KESSEL Staufix FKA

or KESSEL Pumpfix F.

For connection to PVC pipe according to EN 1401-1

and PE-HD connections according to EN 12666-1.

Installation:

Handles groundwater depths up to 2000 mm

Distance from base of chamber to:

Base of inlet approx. 136 mm

Base of outlet approx. 108 mm

Note: Further chamber heights (on request)

3inletsØ160/1outletØ200

H1: 1180

H2: 1680

H3: 2180

H4: 2680

H5: 3180

3inletsØ160/1outletØ160

Conversion kits: see page below

Accessories:

• page 62–63

• Depending on installation depth, entrance

access steps may be required (see page 63)

Standard cover on-site

Accessories Art. no. 86 01 22 / 86 01 16

Conversion kits

for models made on or after Jan 2011

Inspection chamber

including temporary

construction

debris cover

Engineeringsystemsbasebackwater

chamber Ø 1000, for Ø 110 – Ø 200*

Inclusive: Komfort control unit

Cable length: 15 m

1166

Backwater

pumpingPumpfixF

Motorized

backwater valve

Staufix FKA

Backwater valve

Staufix SWA

Compatibility:

Art. no.

80 102

80 104

80 091

Cable extension: page 52

Compatibility:

Engineering systems base backwater

chamber Ø 1000, for Ø 110 – Ø 200*

Inclusive: Komfort control unit

Cable length: 15 m

Cable extension: page 52

Compatibility:

Engineering systems base backwater

chamber Ø 1000, for Ø 110 – Ø 200*

* In-/Outlet Ø 200, hydraulics corresponds to Ø 160

H1: 1180

H2: 1680

H3: 2180

H4: 2680

H5: 3180

88 10

88 15

88 20

88 25

88 30

C

h

a

m

b

e

r

h

e

i

g

h

t

H

1

t

o

H

5

f

r

o

m

5

0

t

o

2

8

0

m

m

P

l

e

a

s

e

s

t

a

t

e

g

r

o

u

n

d

w

a

t

e

r

l

e

v

e

l

T

a

b

o

v

e

b

a

s

e

o

f

c

h

a

m

b

e

r