Chemical and Physical Treatments, what to do

Corrosion protection

The plant thoroughly rinsed must be loaded

again by making the necessary corrosion pro-

tection, using the filming FILMAx+Thermakil

®

in

ratio of 1 - 2 % and letting it circulate into the sy-

stem permanently. This product will in fact have

the capacity to create a layer of coating on the

metal parts making up the system , preserving

them from the precipitation of sludge, rust, sca-

le, algae, etc .

In order to ensure a constant and lasting cor-

rosion protection to the system, we suggest to

check regularly (at least twice a year as required

by the UNI 8065:2019) the pH value that must

always be between 8 and 9.5, while in the pre-

sence of radiators or aluminum elements and

its alloys, the pH must be according to Norm

between 7 and 8.

In case of need of an antifreeze we suggest to

add to the system antifreeze ATIGEL or ALIGEL

in concentrations not inferior to 30 %, in this way

you obtain both antifreeze and good anticorrosi-

ve protection for 3 - 5 years.

In the presence of pipes or carbon steel (iron)

radiators, we suggest, as a further guarantee

protection of the boiler and of the total plant, the

application of the magnetic filter – sludge remo-

ver MAG- NEx HP Series, installing it after the

latest radiator on the return of the boiler.

Heating system

NOT NEW

3 Sludge removal and passivation

of a thermal system

through a special healing

pump Disiflux

2 - 6 hours

Sludge removal

In case a quick cleaning is required due to

an excessive clogging of the system and the

consequent drastic performance reduction, or

when it is not indicated to make the product

circulate with the pump or with the circulator

because of the presence of a new boiler, or

without a boiler, you need the use of the spe-

cial high-efficiency pump DISIFLUx, dosing

ANTINEx+Thermakil

®

in doubled or tripled

percentages compared to the previous condi-

tions , so in ratio of 4 - 6 % of the circulating

liquid for at least 2 - 6 hours, or some more

time until water runs clean. The same pump

will have also the loading and testing function.

Corrosion protection

In summary, as in previous cases , but wi-

thout completely draining the system, you will

perform a backwash with water, later you will

refill the protective FILMAx+Thermakil

®

or al-

ternatively the right concentration of antifree-

ze ATIGEL or ALIGEL ( at least 30 % in order

to obtain besides a good antifreeze action

also proper anticorrosive action).

Also in this case it is recommended, in the

presence of radiators in carbon steel (iron),

the installation after the last radiator on the

return in the boiler, the magnetic filter - slu-

dge remover MAG-NEx HP Seriese specially

in the presence of corrosive phenomena such

as rust scales or incoherent magnetic oxide

(Magnetite).

Watch the new video

The rehabilitation of

Thermal Plants

50

tIHLErrISEASNtAoMrEANtItoN

oIFMPLIANtIS