50
PRESTAZIONI LINEA BOLLITORI
MODELLO
2000 l/h
25
60 °C
2000 l/h
40
70 °C
2000 l/h
51
80° C
2000 l/h
29
70 °C
2000 l/h
36
80° C
OMEGA 2000
SCAMBIATORI FISSI ACQUA TECNICA
INFERIORE
4,2 m2
MANDATA (NELLO SCAMBIATORE)
PORTATA
ΔT
T
Prelievo ACS in continuo
10-45 °C
35 ΔT
POTENZA
PORTATA
59 kW
0,40 l/s
1445 l/h
93 kW
0,64 l/s
2288 l/h
118 kW
0,80 l/s
2890 l/h
SUPERIORE
3,0 m2
MANDATA (NELLO SCAMBIATORE)
PORTATA
ΔT
T
2000 l/h
18
60 °C
Prelievo ACS in continuo
10-45 °C
35 ΔT
POTENZA
PORTATA
42 kW
0,29 l/s
1032 l/h
67 kW
0,45 l/s
1634 l/h
84 kW
0,57 l/s
2064 l/h
PERDITE DI CARICO SCAMBIATORI FISSI ACQUA TECNICA
900
800
700
600
500
400
300
200
100
0
4,2 m2
3,0 m2
0
500
1000
1500
2000
2500
3000
Portata [l/h]
3500
4000
4500
5000
[
m
b
a
r
]
PRELIEVO ACS
ACCUMULO RISCALDATO SOLO NELLA PARTE INFERIORE
T acc.
45 °C
T prim.
10 °C
T prim.
T acc.
ACS PRELEVABILE [lt]
10 min
60 min
55 °C
50 °C
2542
3630
65 °C
60 °C
3346
5135
70 °C
60 °C
3468
5640
80 °C
60 °C
3610
6250
PRELIEVO ACS
ACCUMULO RISCALDATO SOLO NELLA PARTE SUPERIORE
T acc.
45 °C
T prim.
T prim.
T acc.
ACS PRELEVABILE [lt]
10 min
60 min
55 °C
50 °C
955
1780
65 °C
60 °C
1225
2240
70 °C
60 °C
1300
2760
80 °C
60 °C
1395
3280
10 °C
www.dynergysrl.it
BOLLITORI, SERBATOI E CELLE TERMICHE 2023