Terminali Idronici - Hydronic Terminals
Codice - Code
Descrizione - Description
Mod.
MRS1
TM-32
TM-42
STW
SDI.4x3A
TEL42
Morsettiera tipo “Mamut” (min. 5 poli) IP20. Accessorio obbligatorio con comando remoto.
“Mammoth” type terminal board (min. 5 poles) IP20. Mandatory accessory with remote control.
Termostato min temp. acqua T. set 32°C.
Thermostat min temp. water T. set 32°C.
Termostato min temp. acqua T. set 42°C.
Thermostat min temp. water T. set 42°C.
Sonda temp. acqua (in alternativa al termostato “TM”). NTC 10kΩ @25°C, L=600mm.
Water temperature sensor (alternative to “TM” thermostat). NTC 10kΩ @25°C, L=600mm.
FC
FCE
FC
FCE
FC
FCE
FC
FCE
MRS2
Morsettiera tipo "Mamut" (min. 5 poli) IP20 + termostato minima temperatura acqua calda "TM" a 32°C.
"Mammoth" type terminal board (min. 5 poles) IP20 + Minimum hot water temperature thermostat
"TM" set to 32°C.
FC
FCE
CRMI
Gestione unità 2-4 tubi con/senza valvole. Uscite: 1 motore AC~230V 1...3Vel. + 2 valvole ON/OFF,
PWM, 3-Punti.
Control 2-4 pipes unit with/without valves. Output: 1 AC~230V motor 1...3-Speed + 2 valves ON/OFF,
PWM, 3-Point.
FC
CRMI-010
Gestione unità 2-4 tubi. Uscite: 1 motore AC~230V 1...3Vel. + 2 valvole modulanti 0
...10Vdc,
Oppure 1 motore EC~230V 0...10Vdc + 2 valvole modulanti 0...10Vdc o 2 valvole ON/OFF, PWM.
Control 2-4 pipes unit. Output: 1 AC~230V motor 1...3-Speed + 2 modulating valves 0...10Vdc,
or electronic EC~230V motor 0...10Vdc + 2 modulating valves 0...10Vdc or 2 valves ON/OFF, PWM.
FCE
Scheda con 4 uscite da 3A (idonea per controllare
fino a max n° 4 motori 3-Velocità da 3A).
FC
Card with 4 by 3A output (suitable to control up to max No. 4 3-Speed 3A motors).
Scheda madre + Sonda aria + Sonda acqua + Ricevitore I.R. + Telecomando.
FC
Motherboard + Air sensor + Water sensor + I.R. Receiver + I.R. Remote control.
CB2(32)
Commutatore “OFF/3 velocit
à” + Deviatore “Estate/Inverno” + Termostato minima temperatura
acqua “TM” (taratura TM = 32°C).
“OFF/3-speed” switch + “Winter/Summer” switch + Water low temperature thermostat “TM”
(TM setting = 32°C)
FC
CB2(32)-ECM
Interruttore bipolare “Estate/OFF/Inverno” + Comando manuale per la variazione continua della
vel. ventilatore 0
...100% + Termostato minima temperatura acqua calda (inverno) “TM-32”
(taratura TM = 32°C).
“Summer/OFF/Winter” bipolar switch + Manual control for continuous variation of the fan’s speed
0 ... 100% + Minimum hot water temperature thermostat (winter) “TM-32” (TM setting = 32°C).
FCE
CB12(32)
Commutatore “6 velocit
à” + Deviatore “OFF/Estate/Inverno” + Termostato minima temperatura
acqua “TM” (taratura TM = 32°C).
“6-speed” switch + “OFF/Winter/Summer” switch + Water low temperature thermostat “TM”
(TM setting = 32°C).
FC
CBE25
Regolatore 230Vac per gestione unità 2-4 tubi con/senza valvole. Uscite: 1 motore AC~230V 3Vel.
+ 2 valvole ON/OFF, PWM, 3-Punti.
Controller 230Vac for control 2-4 pipes unit with/without valves. Output: 1 AC~230V motor 3Speed
+ 2 valves ON/OFF, PWM, 3-Point.
FC
CBE26
Regolatore 230Vac per gestione unità 2-4 tubi. Uscite: 1 motore AC~230V 3Vel. + 2 valvole
modulanti 0...10Vdc (VL-M010), oppure 1 motore EC~230V 0
...10Vdc (Brush) + 2 valvole
modulanti 0...10Vdc (VL-M010) o 2 valvole ON/OFF (VL-230V opp. 1VL+1RES).
Controller 230Vac for control 2-4 pipes unit. Output: 1 AC~230V motor 3-Speed + 2 modulating
valves 0
...10Vdc (VL-M010), or electronic EC~230V motor 0...10Vdc (Brushless) + 2 modulating
valves 0
...10Vdc (VL-M010) or 2 valves ON/OFF (VL-230V or 1VL+1RES).
FCE
VL21
Kit valvola a 3 vie montato sull’unità completo di attuatore 230V, attacchi DN 3/4’’ M
3-way valve kit mounted on the unit complete with 230V actuator, DN 3/4 ‘’ M connections
FC
FCE
VL31
Kit valvola a 2 vie montato sull’unità completo di attuatore 230V, attacchi DN 3/4’’ M
2-way valve kit mounted on the unit complete with 230V actuator, DN 3/4 ‘’ M connections
FC
FCE
VL22-M010
Kit valvola a 3 vie montato sull’unità completo di attuatore 24V, modulante 0-10V, attacchi DN 3/4’’ M
3-way valve kit mounted on the unit complete with 24V actuator, modulating signal 0-10V,
DN 3/4’’ M connections.
FCE
VL32-M010
Kit valvola a 2 vie montato sull’unità completo di attuatore 24V, modulante 0-10V, attacchi DN 3/4’’ M
2-way valve kit mounted on the unit complete with 24V actuator, modulating signal 0-10V,
DN 3/4 ‘’ M connections.
FCE
CZP
Coppia zoccoli preverniciati bassi H = 90 mm Std
Pair of pre-painted low baseboards H = 90 mm Std
FC
FCE
80