ACCESSORI OPZIONALI - OPTIONAL ACCESSORIES

Codice - Code

Descrizione - Description

Mod.

MRS1

TM-32

TM-42

STW

SDI.4x3A

TEL42

Morsettiera tipo “Mamut” (min. 5 poli) IP20. Accessorio obbligatorio con comando remoto.

“Mammoth” type terminal board (min. 5 poles) IP20. Mandatory accessory with remote control.

Termostato min temp. acqua T. set 32°C.

Thermostat min temp. water T. set 32°C.

Termostato min temp. acqua T. set 42°C.

Thermostat min temp. water T. set 42°C.

Sonda temp. acqua (in alternativa al termostato “TM”). NTC 10kΩ @25°C, L=600mm.

Water temperature sensor (alternative to “TM” thermostat). NTC 10kΩ @25°C, L=600mm.

FC

FCE

FC

FCE

FC

FCE

FC

FCE

MRS2

Morsettiera tipo "Mamut" (min. 5 poli) IP20 + termostato minima temperatura acqua calda "TM" a 32°C.

"Mammoth" type terminal board (min. 5 poles) IP20 + Minimum hot water temperature thermostat

"TM" set to 32°C.

FC

FCE

CRMI

Gestione unità 2-4 tubi con/senza valvole. Uscite: 1 motore AC~230V 1...3Vel. + 2 valvole ON/OFF,

PWM, 3-Punti.

Control 2-4 pipes unit with/without valves. Output: 1 AC~230V motor 1...3-Speed + 2 valves ON/OFF,

PWM, 3-Point.

FC

CRMI-010

Gestione unità 2-4 tubi. Uscite: 1 motore AC~230V 1...3Vel. + 2 valvole modulanti 0

...10Vdc,

Oppure 1 motore EC~230V 0...10Vdc + 2 valvole modulanti 0...10Vdc o 2 valvole ON/OFF, PWM.

Control 2-4 pipes unit. Output: 1 AC~230V motor 1...3-Speed + 2 modulating valves 0...10Vdc,

or electronic EC~230V motor 0...10Vdc + 2 modulating valves 0...10Vdc or 2 valves ON/OFF, PWM.

FCE

Scheda con 4 uscite da 3A (idonea per controllare

fino a max n° 4 motori 3-Velocità da 3A).

FC

Card with 4 by 3A output (suitable to control up to max No. 4 3-Speed 3A motors).

Scheda madre + Sonda aria + Sonda acqua + Ricevitore I.R. + Telecomando.

FC

Motherboard + Air sensor + Water sensor + I.R. Receiver + I.R. Remote control.

CB2(32)

Commutatore “OFF/3 velocit

à” + Deviatore “Estate/Inverno” + Termostato minima temperatura

acqua “TM” (taratura TM = 32°C).

“OFF/3-speed” switch + “Winter/Summer” switch + Water low temperature thermostat “TM”

(TM setting = 32°C)

FC

CB2(32)-ECM

Interruttore bipolare “Estate/OFF/Inverno” + Comando manuale per la variazione continua della

vel. ventilatore 0

...100% + Termostato minima temperatura acqua calda (inverno) “TM-32”

(taratura TM = 32°C).

“Summer/OFF/Winter” bipolar switch + Manual control for continuous variation of the fan’s speed

0 ... 100% + Minimum hot water temperature thermostat (winter) “TM-32” (TM setting = 32°C).

FCE

CB12(32)

Commutatore “6 velocit

à” + Deviatore “OFF/Estate/Inverno” + Termostato minima temperatura

acqua “TM” (taratura TM = 32°C).

“6-speed” switch + “OFF/Winter/Summer” switch + Water low temperature thermostat “TM”

(TM setting = 32°C).

FC

CBE25

Regolatore 230Vac per gestione unità 2-4 tubi con/senza valvole. Uscite: 1 motore AC~230V 3Vel.

+ 2 valvole ON/OFF, PWM, 3-Punti.

Controller 230Vac for control 2-4 pipes unit with/without valves. Output: 1 AC~230V motor 3Speed

+ 2 valves ON/OFF, PWM, 3-Point.

FC

CBE26

Regolatore 230Vac per gestione unità 2-4 tubi. Uscite: 1 motore AC~230V 3Vel. + 2 valvole

modulanti 0...10Vdc (VL-M010), oppure 1 motore EC~230V 0

...10Vdc (Brush) + 2 valvole

modulanti 0...10Vdc (VL-M010) o 2 valvole ON/OFF (VL-230V opp. 1VL+1RES).

Controller 230Vac for control 2-4 pipes unit. Output: 1 AC~230V motor 3-Speed + 2 modulating

valves 0

...10Vdc (VL-M010), or electronic EC~230V motor 0...10Vdc (Brushless) + 2 modulating

valves 0

...10Vdc (VL-M010) or 2 valves ON/OFF (VL-230V or 1VL+1RES).

FCE

VL21

Kit valvola a 3 vie montato sull’unità completo di attuatore 230V, attacchi DN 3/4’’ M

3-way valve kit mounted on the unit complete with 230V actuator, DN 3/4 ‘’ M connections

FC

FCE

VL31

Kit valvola a 2 vie montato sull’unità completo di attuatore 230V, attacchi DN 3/4’’ M

2-way valve kit mounted on the unit complete with 230V actuator, DN 3/4 ‘’ M connections

FC

FCE

VL22-M010

Kit valvola a 3 vie montato sull’unità completo di attuatore 24V, modulante 0-10V, attacchi DN 3/4’’ M

3-way valve kit mounted on the unit complete with 24V actuator, modulating signal 0-10V,

DN 3/4’’ M connections.

FCE

VL32-M010

Kit valvola a 2 vie montato sull’unità completo di attuatore 24V, modulante 0-10V, attacchi DN 3/4’’ M

2-way valve kit mounted on the unit complete with 24V actuator, modulating signal 0-10V,

DN 3/4 ‘’ M connections.

FCE

CZP

Coppia zoccoli preverniciati bassi H = 90 mm Std

Pair of pre-painted low baseboards H = 90 mm Std

FC

FCE

80