Unità interna
LCG700C
LCG850C
LCG1000C
LCG1000C
LCG1200C
LCG1200C
LCG1400C
LCG1400C
LCG1600C
Unità esterna
LCG700
LCG850
LCG1000
LCG1000T
LCG1200
LCG1200T
LCG1400
LCG1400T
LCG1600T
Prestazioni in raffrescamento nominali
Potenza frigorifera (1)
Potenza assorbita a freddo (1)
EER (2)
Umidità asportata
kW
7,00
kW
2,05
W/W
3,41
l/h
2,4
8,50
10,00
10,00
12,10
12,10
13,40
13,40
14,50
2,80
3,15
3,00
4,10
4,05
4,65
4,70
5,20
3,04
3,17
3,33
2,95
2,99
2,88
2,85
2,79
Prestazioni in raffrescamento minime e massime
2,9
2,40/9,00
0,50/3,95
12,7
6,10
A++
3,5
3,20/11,00
0,60/4,05
13,8
6,10
4,0
4,1
3,20/11,00
3,60/12,80
0,60/4,05
0,70/4,85
5,0
17,5
6,10
6,10
4,0
4,7
3,60/12,80
6,00/14,20
0,60/5,30
0,80/5,50
5,9
20,8
6,10
6,10
4,3
5,3
6,00/14,20
6,50/15,00
0,80/5,95
0,85/5,95
7,2
7,6
6,10
6,10
Potenza frigorifera
Potenza assorbita a freddo
Corrente assorbita a freddo
SEER
min / max
min / max
max
kW
2,40/8,00
kW
0,40/3,50
A
8,8
W/W
7,20
A++
Efficienza stagionale
Classe efficienza energetica (3)
Pdesignc
Consumo elettrico annuo
A++
A++
-
-
-
-
-
Prestazioni in riscaldamento nominali
Potenza termica (4)
Potenza assorbita a caldo (4)
COP (2)
-
-
13,50
15,50
4,15
4,35
3,25
3,56
3,60/14,50
3,90/16,00
0,60/5,30
0,80/5,50
3,8
3,6
-
-
-
-
-
-
5,3
5,5
8,0
25,0
-
-
15,50
17,00
4,45
4,80
3,48
3,54
3,90/16,00
4,50/17,50
0,80/5,95
0,85/5,95
4,0
3,8
-
-
-
-
-
-
6,0
6,0
9,0
9,0
1900/1690/1480/1140 2000/1880/1620/1430
kW
7,0
8,5
10,0
10,0
-
-
-
-
-
kWh/
340
472
566
annum
kW
8,00
8,80
12,00
kW
2,20
2,65
3,55
W/W
3,64
3,32
3,38
553
-
12,00
13,50
3,40
4,20
3,53
3,21
3,00/13,50
3,60/14,50
0,60/4,05
0,70/4,85
4,0
3,8
A+
-
9,0
-
3168
-
4,7
4,9
7,0
22,0
Centrifugo inverter
1500/1470/1380/1220 1800/1690/1470/1260 1800/1690/1470/1260
Prestazioni in riscaldamento minime e massime
Potenza termica
min / max
kW
Potenza assorbita a caldo
min / max
kW
Efficienza stagionale (clima temperato)
SCOP
Classe efficienza energetica (3)
2,20/9,00
2,40/9,50
3,00/13,50
0,45/3,50
0,50/3,95
0,60/4,05
3,9
4,0
4,0
A
A+
A+
Pdesignh
kW
6,4
7,2
9,0
Consumo elettrico annuo
kWh/
2297
2616
3139
annum
Dati elettrici
Potenza nominale assorbita (5)
kW
Corrente nominale assorbita (5)
A
Ventilatore
Tipo di ventilatore
Tipo
3,5
4,0
4,1
16,0
18,0
18,5
Portata d’aria
turbo/max/med/min
m
3
/h 1100/1050/960/870 1400/1310/1180/1040 1500/1470/1380/1220
1900/1690/1480/1140
Pressione sonora (6)
turbo/max/med/min
Tubazioni frigorifere
dB(A) 43,0/42,0/40,0/39,0 49,0/47,0/44,0/41,0 50,0/48,0/46,0/42,0 50,0/48,0/46,0/42,0 51,0/49,0/46,0/42,0 51,0/49,0/46,0/42,0 52,0/51,0/48,0/45,0 52,0/51,0/48,0/45,0 54,0/52,0/50,0/48,0
Diametro attacchi
mm
frigoriferi liquido
(inch)
Diametro attacchi
mm
frigoriferi gas
(inch)
Diametro scarico condensa
mm
Alimentazione
Dimensioni
mm
9,52 (3/8”)
15,9 (5/8")
30,0
220-240V ~
50Hz
9,52 (3/8”)
15,9 (5/8")
30,0
220-240V ~
50Hz
9,52 (3/8”)
15,9 (5/8")
30,0
220-240V ~
50Hz
9,52 (3/8”)
15,9 (5/8")
30,0
380-415V
3N ~ 50Hz
9,52 (3/8”)
15,9 (5/8")
30,0
220-240V ~
50Hz
9,52 (3/8”)
15,9 (5/8")
30,0
380-415V
3N ~ 50Hz
9,52 (3/8”)
15,9 (5/8")
30,0
220-240V ~
50Hz
840X840X290
9,52 (3/8”)
15,9 (5/8")
30,0
380-415V
3N ~ 50Hz
9,52 (3/8”)
15,9 (5/8")
30,0
380-415V
3N ~ 50Hz
(1) Raffrescamento (EN-14511 e EN-14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità massima; lunghezza linee frigorifere 5 m.
(2) EER/COP in accordo alla Normativa (EN-14511), dichiarati solo al fine delle detrazioni
fiscali in vigore all’atto della realizzazione di questa pubblicazione.
(3) Dati in accordo con il regolamento delegato (UE) N.626/2011.
(4) Riscaldamento (EN-14511 e EN-14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità massima; lunghezza linee frigorifere 5 m.
(5) La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN-60335-1 e EN-60335-2-40.
(6) Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.
840X840X240
39