Unità interna
LCG350F
LCG500F
LCG700F
LCG850F
LCG1000F
LCG1200F
LCG1400F
Unità esterna
LCG350
LCG500
LCG700
LCG850
LCG1000
LCG1200
LCG1400
Prestazioni in raffrescamento nominali
Potenza frigorifera (1)
kW
Potenza assorbita a freddo (1)
kW
EER (2)
W/W
3,50
0,95
3,89
0,5
0,90/4,00
0,20/1,35
4,0
6,7
A++
3,5
177
4,00
1,05
4,21
5,00
1,55
3,23
1,6
1,60/5,50
0,30/1,75
6,5
6,1
A++
5,0
284
5,50
1,60
3,44
1,50/6,00
0,30/1,75
4,0
A+
4,0
1394
1,8
8,0
850/800/700/600
44,0/42,0/39,0/36,0
6,35 (1/4")
12,7 (1/2")
17,0
870X235X665
7,00
8,50
10,00
12,10
13,40
1,90
2,80
3,30
3,90
4,40
3,68
3,04
3,03
3,10
3,05
1,4
2,6
3,1
3,3
3,3
Umidità asportata
Prestazioni in raffrescamento minime e massime
Potenza frigorifera
Potenza assorbita a freddo
Corrente assorbita a freddo
Efficienza stagionale
SEER
Classe efficienza energetica (3)
Pdesignc
Consumo elettrico annuo
min / max
min / max
max
l/h
kW
kW
A
W/W
kW
kWh/
annum
kW
kW
W/W
2,40/8,00
0,40/3,50
8,6
6,8
A++
7,0
359
8,00
2,45
3,27
2,20/9,00
0,45/3,50
3,9
A
6,4
2295
3,5
16,0
1300/1220/1090/940
45,0/44,0/41,0/38,0
9,52 (3/8")
15,9 (5/8")
17,0
1200X235X665
2,40/9,00
3,20/11,00
3,60/12,80
6,00/14,20
0,50/3,95
0,60/4,05
0,70/4,85
0,80/5,50
12,7
6,1
A++
8,5
477
8,80
2,65
3,32
14,5
15,7
19,5
6,1
6,1
6,3
A++
-
-
10,0
-
-
573
-
-
Prestazioni in riscaldamento nominali
Potenza termica (4)
Potenza assorbita a caldo (4)
COP (2)
Prestazioni in riscaldamento minime e massime
Potenza termica
min / max
Potenza assorbita a caldo
min / max
Efficienza stagionale (clima temperato)
SCOP
Classe efficienza energetica (3)
Pdesignh
Consumo elettrico annuo
Dati elettrici
Potenza nominale assorbita (5)
Corrente nominale assorbita (5)
12,00
3,60
3,33
13,50
15,50
3,95
4,35
3,42
3,56
kW
0,90/4,50
kW
0,20/1,35
4,0
A+
kW
3,1
kWh/
1040
annum
kW
1,4
A
6,0
Tipo
m
3
/h
650/610/530/460
dB(A) 39,0/36,0/32,0/28,0
mm
6,35 (1/4”)
(inch)
mm
9,52 (3/8”)
(inch)
mm
17,0
mm
870X235X665
2,40/9,50
3,00/13,50
3,60/14,50
3,90/16,00
0,50/3,95
0,60/4,05
0,70/4,85
0,80/5,50
Ventilatore
Tipo di ventilatore
Portata d’aria
Pressione sonora (6)
Tubazioni frigorifere
turbo/max/med/min
turbo/max/med/min
4,0
A+
7,2
2577
4,0
18,0
Centrifugo inverter
1500/1380/1200/1020
49,0/47,0/43,0/39,0
9,52 (3/8")
15,9 (5/8")
17,0
220-240V ~ 50Hz
1200X235X665
4,0
A+
9,0
3149
4,1
18,5
1600/1500/1350/1260
49,0/47,0/45,0/43,0
9,52 (3/8")
15,9 (5/8")
17,0
1200X235X665
3,8
-
-
-
4,9
22,0
1800/1700/1540/1400
49,0/47,0/44,0/42,0
9,52 (3/8")
15,9 (5/8")
17,0
1570X235X665
3,7
-
-
-
5,5
25,0
2100/2000/1800/1480
52,0/50,0/48,0/44,0
9,52 (3/8")
15,9 (5/8")
17,0
1570X235X665
Diametro attacchi frigoriferi liquido
Diametro attacchi frigoriferi gas
Diametro scarico condensa
Alimentazione
Dimensioni
(1) Raffrescamento (EN-14511 e EN-14825) temperatura aria ambiente 27 °C b.s. / 19 °C b.u.; temperatura aria esterna 35 °C; velocità massima; lunghezza linee frigorifere 5 m.
(2) EER/COP in accordo alla Normativa (EN-14511), dichiarati solo al fine delle detrazioni
fiscali in vigore all’atto della realizzazione di questa pubblicazione.
(3) Dati in accordo con il regolamento delegato (UE) N.626/2011.
(4) Riscaldamento (EN-14511 e EN-14825) temperatura aria ambiente 20 °C b.s.; temperatura aria esterna 7 °C b.s. / 6 °C b.u.; velocità massima; lunghezza linee frigorifere 5 m.
(5) La potenza nominale assorbita (corrente nominale assorbita), è la massima potenza elettrica assorbita (corrente massima assorbita) dal sistema, in accordo con la normativa EN-60335-1 e EN-60335-2-40.
(6) Pressione sonora misurata in camera anecoica a 1,5 m di distanza frontale.
40