COMMERCIAL BIOSHIELD

®

CLP

UV SYSTEM

1. Establishing flow rate requirements in GPM is critical to selecting the correct UV system for your application.

2. Know your UVT and dose requirement. UVT is the measure of UV-C light transmittance (254nm) in water.

Dose is a factor of UV light intensity and contact time.

3. Choose your BioShield UV system model. Select desired dose column below. Identify maximum flow rate that meets system

flow rate requirement. Complete this step for model CLP4 or CLP6 and with provided vessel and power enclosure dimensions,

choose the best model suited for the mechanical space. *Note max flow rate for desired port size on each model.

SIZING YOUR BIOSHIELD UV SYSTEM

Model

1

Lamps/

Watts

Max Flow

Rate (GPM)

40 mJ/cm

2

Max Flow

Rate (GPM)

60 mJ/cm

2

Port

Size

1

Max.

Flow

Amps

Max Load

UV Vessel

Dimensions

2

(A x B x C)

Power Enclosure

Dimensions

(H x W x D)

Max.

PSI

ONLY AVAILABLE IN 120VAC

CLP41A6-XN

1/130

49

33

2"

64

2.1/1.0

56" x 6"x 47"

24.6" x 20.2" x 10.6"

100

CLP42A6-XN

2/130

90

60

3"

144

3.9/2.0

56" x 6" x 47"

24.6" x 20.2" x 10.6"

100

CLP43A6-XN

3/130

125

83

3"

144

4"

251

5.8/2.9

56" x 6" x 47"

24.6" x 20.2" x 10.6"

100

CLP43A8-XN

3/130

167

111

4"

251

5.8/2.9

62" x 8" x 51"

24.6" x 20.2" x 10.6"

100

CLP44A8-XN

4/130

227

151

4"

251

6"

569

7.5/3.7

62" x 8" x 51"

24.6" x 20.2" x 10.6"

100

CLP45A8-XN

5/130

272

181

4"

251

9.4/4.7

62" x 8" x 51"

30.5" x 24.9" x 12.6"

100

6"

569

CLP46A10-XN

6/130

365

244

6"

569

11.2/5.6

64" x 10" x 51"

30.5" x 24.9" x 12.6"

75

CLP47A10-XN

7/130

430

287

6"

569

13.3/6.5

64" x 10" x 51"

30.5" x 24.9" x 12.6"

75

8"

996

CLP47A12-XN

7/130

492

328

6"

569

8"

996

13.3/6.5

69" x 12" x 51"

30.5" x 24.9" x 12.6"

50

CLP48A12-XN

8/130

555

369

6"

569

15.0/7.5

69" x 12" x 51"

30.5" x 24.9" x 12.6"

50

8"

996

ONLY AVAILABLE IN 240VAC

CLP61A6-XN

1/320

113

75

3"

144

4"

251

1.6

85" x 6" x 76"

24.6 " x 20.2" x 10.6" 100

CLP62A6-XN

2/320

200

133

3"

144

3

85" x 6" x 76"

24.6 " x 20.2" x 10.6"

100

4"

251

CLP63A6-XN

3/320

279

186

3"

144

4"

251

4.5

85" x 6" x 76"

24.6 " x 20.2" x 10.6" 100

CLP63A8-XN

3/320

372

247

4"

251

4.5

85" x 6" x 76"

24.6 " x 20.2" x 10.6"

100

6"

569

CLP64A8-XN

4/320

505

336

4"

251

6"

569

6

85" x 6" x 76"

24.6 " x 20.2" x 10.6" 100

CLP65A8-XN

5/320

606

403

6"

569

7.5

85" x 6" x 76"

30.5" x 24.1" x 12.6"

100

CLP66A10-XN

6/320

814

542

6"

569

8"

996

9

88" x10"x 76"

30.5" x 24.1" x 12.6"

75

CLP67A10-XN

7/320

953

638

6"

569

11

88" x10"x 76"

30.5" x 24.1" x 12.6"

75

8"

996

CLP67A12-XN

7/320

1095

729

8"

996

10"

1567

11

90" x 12" x 76"

30.5" x 24.1" x 12.6"

50

CLP68A12-XN

8/320

1235

823

8"

996

13

90" x 12" x 76"

30.5" x 24.1" x 12.6"

50

10"

1567

CLP69A14-XN

9/320

1462

974

12"

2218

14

92" x 14" x 76"

40.4" x 32.5" x 12.6"

50

CLP610A16-XN

10/320

1690

1127

12"

2218

16

94" x 16" x 76"

40.4" x 32.5" x 12.6"

50

14"

2650

1

When ordering: Replace 'X' in part number with requested flange size; eg. '2' for two-inch flange.

2

Vessel dimension "C" represents clearance requirement for glassware maintenance.

“Sanitizer” is an industry term of art and is not intended to imply any antimicrobial capabilities.

S

A

N

I

T

I

Z

E

R

S

A

N

D

W

A

T

E

R

Q

U

A

L

I

T

Y

295