1. Establishing flow rate requirements in GPM is critical to selecting the correct UV system for your application.
2. Know your UVT and dose requirement. UVT is the measure of UV-C light transmittance (254nm) in water.
Dose is a factor of UV light intensity and contact time.
3. Choose your BioShield UV system model. Select desired dose column below. Identify maximum flow rate that meets system
flow rate requirement. Complete this step for model CLP4 or CLP6 and with provided vessel and power enclosure dimensions,
choose the best model suited for the mechanical space. *Note max flow rate for desired port size on each model.
Model
1
Lamps/
Watts
Max Flow
Rate (GPM)
40 mJ/cm
2
Max Flow
Rate (GPM)
60 mJ/cm
2
Port
Size
1
Max.
Flow
Amps
Max Load
UV Vessel
Dimensions
2
(A x B x C)
Power Enclosure
Dimensions
(H x W x D)
Max.
PSI
ONLY AVAILABLE IN 120VAC
CLP41A6-XN
1/130
49
33
2"
64
2.1/1.0
56" x 6"x 47"
24.6" x 20.2" x 10.6"
100
CLP42A6-XN
2/130
90
60
3"
144
3.9/2.0
56" x 6" x 47"
24.6" x 20.2" x 10.6"
100
CLP43A6-XN
3/130
125
83
3"
144
4"
251
5.8/2.9
56" x 6" x 47"
24.6" x 20.2" x 10.6"
100
CLP43A8-XN
3/130
167
111
4"
251
5.8/2.9
62" x 8" x 51"
24.6" x 20.2" x 10.6"
100
CLP44A8-XN
4/130
227
151
4"
251
6"
569
7.5/3.7
62" x 8" x 51"
24.6" x 20.2" x 10.6"
100
CLP45A8-XN
5/130
272
181
4"
251
9.4/4.7
62" x 8" x 51"
30.5" x 24.9" x 12.6"
100
6"
569
CLP46A10-XN
6/130
365
244
6"
569
11.2/5.6
64" x 10" x 51"
30.5" x 24.9" x 12.6"
75
CLP47A10-XN
7/130
430
287
6"
569
13.3/6.5
64" x 10" x 51"
30.5" x 24.9" x 12.6"
75
8"
996
CLP47A12-XN
7/130
492
328
6"
569
8"
996
13.3/6.5
69" x 12" x 51"
30.5" x 24.9" x 12.6"
50
CLP48A12-XN
8/130
555
369
6"
569
15.0/7.5
69" x 12" x 51"
30.5" x 24.9" x 12.6"
50
8"
996
ONLY AVAILABLE IN 240VAC
CLP61A6-XN
1/320
113
75
3"
144
4"
251
1.6
85" x 6" x 76"
24.6 " x 20.2" x 10.6" 100
CLP62A6-XN
2/320
200
133
3"
144
3
85" x 6" x 76"
24.6 " x 20.2" x 10.6"
100
4"
251
CLP63A6-XN
3/320
279
186
3"
144
4"
251
4.5
85" x 6" x 76"
24.6 " x 20.2" x 10.6" 100
CLP63A8-XN
3/320
372
247
4"
251
4.5
85" x 6" x 76"
24.6 " x 20.2" x 10.6"
100
6"
569
CLP64A8-XN
4/320
505
336
4"
251
6"
569
6
85" x 6" x 76"
24.6 " x 20.2" x 10.6" 100
CLP65A8-XN
5/320
606
403
6"
569
7.5
85" x 6" x 76"
30.5" x 24.1" x 12.6"
100
CLP66A10-XN
6/320
814
542
6"
569
8"
996
9
88" x10"x 76"
30.5" x 24.1" x 12.6"
75
CLP67A10-XN
7/320
953
638
6"
569
11
88" x10"x 76"
30.5" x 24.1" x 12.6"
75
8"
996
CLP67A12-XN
7/320
1095
729
8"
996
10"
1567
11
90" x 12" x 76"
30.5" x 24.1" x 12.6"
50
CLP68A12-XN
8/320
1235
823
8"
996
13
90" x 12" x 76"
30.5" x 24.1" x 12.6"
50
10"
1567
CLP69A14-XN
9/320
1462
974
12"
2218
14
92" x 14" x 76"
40.4" x 32.5" x 12.6"
50
CLP610A16-XN
10/320
1690
1127
12"
2218
16
94" x 16" x 76"
40.4" x 32.5" x 12.6"
50
14"
2650
1
When ordering: Replace 'X' in part number with requested flange size; eg. '2' for two-inch flange.
2
Vessel dimension "C" represents clearance requirement for glassware maintenance.
‡
“Sanitizer” is an industry term of art and is not intended to imply any antimicrobial capabilities.