296
VALVES
POOL
HEATER
BY-PASS
UV
CITY WATER
FILTERS
MAKE UP TANK
TO SEWER
PUMP
CHLORINE INJECTION
pH STABILIZER
Vertical Installation
Horizontal Installation
VACUUM LINE
SKIMMER
RETURN INLETS
MAIN DRAINS
OVERFLOW DRAINS
1. Position the BioShield UV System after the pool filters so it receives solids-free water.
2. The BioShield UV vessel is equipped with various sensor ports (UV intensity and Water Over-Temperature
Protection Sensors). All sensor ports are clearly labeled on the vessel based on their respective function.
Additionally, the vessel is equipped with a 1/2" threaded drain port for installation of the Drain Valve Assembly.
3. For horizontal or vertical piping installation, it is recommended to install a piping bypass manifold(as shown) which
will allow for BioShield UV System removal from the filter-loop without disrupting water flow or filter operation.
Isolation Valves are necessary for vessel removal and chemical cleaning procedure.
4. Always install BioShield UV System's with the outlet port facing upward, allowing trapped air to escape. Trapped
air can result in rupture or heat damage to the vessel.
5. Provide enough space around the electrical end of the BioShield UV System to allow for easy removal of the UV
lamp and quartz sleeves. A 46" clearance for CLP4 models and 76" clearance for CLP6 models is required.
6. Do not install or operate any UV system without thoroughly reading the operators manual.
‡
“Sanitizer” is an industry term of art and is not intended to imply any antimicrobial capabilities.