COMMERCIAL BIOSHIELD

®

UV SYSTEM

VALVES

POOL

HEATER

BY-PASS

UV

CITY WATER

FILTERS

MAKE UP TANK

TO SEWER

PUMP

CHLORINE INJECTION

pH STABILIZER

Vertical Installation

Horizontal Installation

BioShield UV System Installation:

VACUUM LINE

SKIMMER

RETURN INLETS

MAIN DRAINS

OVERFLOW DRAINS

1. Position the BioShield UV System after the pool filters so it receives solids-free water.

2. The BioShield UV vessel is equipped with various sensor ports (UV intensity and Water Over-Temperature

Protection Sensors). All sensor ports are clearly labeled on the vessel based on their respective function.

Additionally, the vessel is equipped with a 1/2" threaded drain port for installation of the Drain Valve Assembly.

3. For horizontal or vertical piping installation, it is recommended to install a piping bypass manifold(as shown) which

will allow for BioShield UV System removal from the filter-loop without disrupting water flow or filter operation.

Isolation Valves are necessary for vessel removal and chemical cleaning procedure.

4. Always install BioShield UV System's with the outlet port facing upward, allowing trapped air to escape. Trapped

air can result in rupture or heat damage to the vessel.

5. Provide enough space around the electrical end of the BioShield UV System to allow for easy removal of the UV

lamp and quartz sleeves. A 46" clearance for CLP4 models and 76" clearance for CLP6 models is required.

6. Do not install or operate any UV system without thoroughly reading the operators manual.