There is no pressure in the pipe
of domestic hot water arriving to
or coming from the accumulator
Pipe and/or accumulator
The hot water accumulator has not heated up yet
The primary circuit is not sufficiently filled
Presence of limestone deposits
inside the accumulator
The primary circuit is not sufficiently filled
Hot water thermostatic mixer tap
is incorrectly regulated
Abundant sun exposure and little use of
hot water heated water contained in the
accumulator up excessively
Overpressure in the primary circuit due to the
prolonged inactivity of the system in high summer
Overpressure in the primary circuit due
to abundant sun exposure and accumulator
totally empty of water
Leak, mechanical breakage or
damage due to frost
Mechanical breakage or damage due to frost
No water runs from the hot water tap
After putting into service, only cold water
runs from the hot water tap.
After long operation and despite the sun
being strong only warm water runs from
the hot water tap
Very hot water runs from the hot water
tap after prolonged absence
The safety valve has opened
Presence of water or heat-carrying fluid
leak in the system
One of the hot water collectors or the
water boiler is damaged
Open the relevant stop taps
Defrost pipes or the accumulator using abundant hot water
and make sure water has not caused any damage. In case of frost,
drain residual water completely to prevent ice from causing damage.
Wait
Integrate with ALIGeL HC20 BIo o ALIGeL HC30 BIo
using SOLARFLUx pump
Clean the accumulator and remove scales using ZINCONEx
or ZINCONEx-LQ and DISINEx 18 K pump
Check tightness of the primary circuit couplings using a UV lamp
and if necessary repair them. Check the safety valve, if necessary replace it.
Fill the primary circuit in using ALIGEL HC20 BIO o ALIGEL HC30 BIO
Position the hot water thermostatic mixer tap to 60 °C
Add cold water or have a hot water thermostatic mixer tap assembled
In the future, in case of prolonged absence or if the accumulator
has been emptied, cover the collector
If necessary fill the primary circuit in with
ALIGEL HC20 BIO o ALIGEL HC30 BIO, ALIGEL
Put the system out of service.
Detect the leak and repair it using FASTOP SOLAR
Put the system out of service. Replace the damaged element and fill
the system in with ALIGEL HC20 BIO o ALIGEL HC30 BIO.
69