PRESTAZIONI LINEA BOLLITORI

59

PRELIEVO ACS

MODELLO

SCAMBIATORI FISSI ACQUA TECNICA

INFERIORE

1,7 m2

MANDATA (NELLO SCAMBIATORE)

PORTATA

ΔT

T

2000 l/h

10

60 °C

2000 l/h

16

70 °C

2000 l/h

20

80° C

MANDATA (NELLO SCAMBIATORE)

PORTATA

ΔT

T

2000 l/h

27

60 °C

2000 l/h

43

70 °C

2000 l/h

54

80° C

ACCUMULO RISCALDATO SOLO NELLA PARTE INFERIORE

HYDYRO2BT505000R2

Prelievo ACS in continuo

10-45 °C

35 ΔT

POTENZA

PORTATA

24 kW

0,16 l/s

585 l/h

38 kW

0,26 l/s

926 l/h

48 kW

0,32 l/s

1170 l/h

SUPERIORE

4,5 m2

Prelievo ACS in continuo

10-45 °C

35 ΔT

POTENZA

PORTATA

63 kW

0,43 l/s

1548 l/h

100 kW

0,68 l/s

2451 l/h

126 kW

0,86 l/s

3096 l/h

PERDITE DI CARICO SCAMBIATORI FISSI ACQUA TECNICA

250

200

150

100

50

0

1,7 m2

4,5 m2

0

500

1000

1500

2000

2500

3000

Portata [l/h]

3500

4000

4500

5000

[

m

b

a

r

]

T acc.

45 °C

T prim.

10 °C

T prim.

T acc.

ACS PRELEVABILE [lt]

10 min

60 min

55 °C

50 °C

642

1005

65 °C

60 °C

856

1398

70 °C

60 °C

893

1540

80 °C

60 °C

935

1725

PRELIEVO ACS

ACCUMULO RISCALDATO SOLO NELLA PARTE SUPERIORE

T acc.

45 °C

T prim.

T prim.

T acc.

ACS PRELEVABILE [lt]

10 min

60 min

55 °C

50 °C

258

670

65 °C

60 °C

363

860

70 °C

60 °C

400

1140

80 °C

60 °C

443

1420

10 °C

BOLLITORI, SERBATOI E CELLE TERMICHE 2023