60

PRESTAZIONI LINEA BOLLITORI

MODELLO

2000 l/h

23

70 °C

2000 l/h

29

80° C

SUPERIORE

4,3 m2

MANDATA (NELLO SCAMBIATORE)

PORTATA

ΔT

T

2000 l/h

26

60 °C

2000 l/h

41

70 °C

2000 l/h

52

80° C

HYDRO BT 800 R2

Y R2 750

SCAMBIATORI FISSI ACQUA TECNICA

INFERIORE

2,4 m2

MANDATA (NELLO SCAMBIATORE)

PORTATA

ΔT

T

2000 l/h

14

60 °C

Prelievo ACS in continuo

10-45 °C

35 ΔT

POTENZA

PORTATA

34 kW

0,23 l/s

826 l/h

53 kW

0,36 l/s

1307 l/h

67 kW

0,46 l/s

1651 l/h

Prelievo ACS in continuo

10-45 °C

35 ΔT

POTENZA

PORTATA

60 kW

0,41 l/s

1479 l/h

95 kW

0,65 l/s

2342 l/h

120 kW

0,82 l/s

2958 l/h

PERDITE DI CARICO SCAMBIATORI FISSI ACQUA TECNICA

250

200

150

100

50

0

2,4 m2

4,3 m2

0

500

1000

1500

2000

2500

3000

Portata [l/h]

3500

4000

4500

5000

[

m

b

a

r

]

PRELIEVO ACS

ACCUMULO RISCALDATO SOLO NELLA PARTE INFERIORE

T acc.

45 °C

T prim.

10 °C

T prim.

T acc.

ACS PRELEVABILE [lt]

10 min

60 min

55 °C

50 °C

962

1485

65 °C

60 °C

1280

2070

70 °C

60 °C

1334

2280

80 °C

60 °C

1395

2550

PRELIEVO ACS

ACCUMULO RISCALDATO SOLO NELLA PARTE SUPERIORE

T acc.

45 °C

T prim.

T prim.

T acc.

ACS PRELEVABILE [lt]

10 min

60 min

55 °C

50 °C

374

858

65 °C

60 °C

507

1094

70 °C

60 °C

551

1416

80 °C

60 °C

603

1738

10 °C

www.dynergysrl.it

BOLLITORI, SERBATOI E CELLE TERMICHE 2023